<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>MDH</ParameterFamily>
<Syntax>
apl tabletransferposz
</Syntax>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Magnus_VLF</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
This NVS parameter holds the plate table transfer height Z-axis position in mm.
This is the Z-height that the table moves to before handing off
the plate to the fetcher. The firmware verifies that the transfer table is at the
correct location by reading the eject height sensor. If the sensor is false when the
table is at the handoff position the firmware will suspend with an error message.
Increasing this parameter moves the table further down towards the plate stack
during the plate handoff to the fetcher.
</text></DescriptionText>
</Description>
<Availability>
<DescriptionText><text>
This parameter is available.
</text></DescriptionText>
</Availability>
<Default>
<UnnumberedList>
<li>120.000 [mm]</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0.000 to 200.000 [mm]</li>
</UnnumberedList>
</Range>
<LastModified>
17-Aug-2006
Created
</LastModified>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Access>
Normal
</Access>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:59 2008 PST
</Updated>
<Links>
</Links>
</Parameter>